NSN 5925-01-051-5288 is available in the following condition(s).
NS:
5
NE:
1
06/27/2024 was the last date inventory was updated
for this national stock number.
Availability
Send us a request for quote for this nsn with your required quantity and basic reply-to information
and our team will send you a price quote via email immediatley. If you have any questions call us at
1 (405) 213-0075
Have a Question?
CALL 1 (405) 213-0075
Manufacturer Datasheet
SKU: 5925-01-051-5288 Model: 3192043
MRC
Name
Detail
MRC:
AAQL
Body Style
Multipole-multiple actuator type
MRC:
ABTD
Mounting Slot Width
0.164 inches
MRC:
ADAQ
Body Length
5.800 inches
MRC:
ADAT
Body Width
3.168 inches
MRC:
ADAU
Body Height
2.609 inches
MRC:
ADTV
Case Material
Plastic
MRC:
AEBP
Center To Center Distance Between Terminals Parallel To Length
3.547 inches
MRC:
AEBQ
Center To Center Distance Between Terminals Parallel To Width
1.026 inches
MRC:
AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.781 inches
MRC:
AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches
MRC:
AFJN
Fragility Factor
Moderately rugged
MRC:
AJEC
Boss Height
0.218 inches
MRC:
AKPX
Pole Quantity
3
MRC:
APNQ
Arc Quenching Method
Magnetic blowout
MRC:
AXHR
Mounting Facility Type And Quantity
6 threaded hole and 6 slot
MRC:
BBRG
Storage Type
General purpose warehouse
MRC:
BBRJ
Special Handling Feature
Magnetic
MRC:
CMLP
Thready Qty Per Inch (tpi)
32
MRC:
CPLM
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac first location2.0 amperes ac second location10.0 amperes dc third location
MRC:
CPRF
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac first location480.0 ac second location28.0 dc third location
MRC:
CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location5000.0 ac second location5000.0 dc third location
MRC:
CPRH
Circuit Protection Type
Overcurrent all locations
MRC:
CPRJ
Trip Release Method
Magnetic all locations
MRC:
CPRL
Trip Release Characteristic
Time delay all locations
MRC:
CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
MRC:
CPRQ
Reset Method
Manual
MRC:
CPRR
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRT
Manual Actuator Type And Quantity
3 toggle
MRC:
CPRW
Actuator Function
Trip-reset
MRC:
CPRX
Actuator Position Designation
At each pole
MRC:
CPRY
External Actuator Linkage Arrangement
One, two, and three linked
MRC:
CPSM
Internal Trip Release Configuration
Series trip all locations
MRC:
CQJX
Thread Size
0.138 inches
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct all locations and 0.600 at 200 pct all locations
MRC:
CQXF
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
MRC:
FREQ
Frequency In Hertz
50.0 first location or 60.0 first location50.0 second location or 60.0 second location
MRC:
PKWT
Unpackaged Unit Weight
2.000 pounds
MRC:
THSD
Thread Series Designator
Unc
MRC:
TTQY
Terminal Type And Quantity
6 threaded stud
MRC:
--
NSN
5925010515288
MRC:
--
Supply Class
#5925 - Circuit Breakers
MRC:
--
PMIC
No precious metal content.
MRC:
--
HMIC
No information in HMIRS. Hazardous material unknown.
Factory New (FN), New Material (NE), New Unused Surplus (NS), Overhauled (OH), Serviceable (SV),
Repairable (RP), and AS Removed / Used (AR) material will be accompanied by a Certificate of Conformance,
and any other documents/trace when applicable.
Delivery
Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.
Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.
Satisfaction
Your satisfaction is our success! At NationalStockNumber.parts
we believe that we have the best quality service out there. If you run
into any issues, we are here to solve them! Contact us by phone or email at any time.