NSN 5925-00-196-3997

Circuit Breaker

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
EA
NIIN:
001963997

Availability

Send us a request for quote for this nsn with your required quantity and basic reply-to information and our team will send you a price quote via email immediatley. If you have any questions call us at 1 (405) 213-0075

NSN:
5925-00-196-3997
Qty:
Your Name:
Email Address:
Phone Number:
Reference:
Company:
Have a Question?
CALL 1 (405) 213-0075
Manufacturer Datasheet

SKU: 5925-00-196-3997 Model: 150-0866

MRC
Name
Detail
MRC:
AAQL
Body Style
Multipole-single actuator type
MRC:
ABTD
Mounting Slot Width
0.187 inches
MRC:
ADAQ
Body Length
17.562 inches
MRC:
ADAT
Body Width
12.750 inches
MRC:
ADAU
Body Height
17.000 inches
MRC:
ADTV
Case Material
Metal
MRC:
AEBP
Center To Center Distance Between Terminals Parallel To Length
1.375 inches
MRC:
AEBQ
Center To Center Distance Between Terminals Parallel To Width
3.625 inches
MRC:
AEBV
Unthreaded Mounting Hole Diameter
0.500 inches
MRC:
AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
11.625 inches
MRC:
AEGJ
Switch Contact Arrangement
Single pole, double throw
MRC:
AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
10.562 inches
MRC:
AJEC
Boss Height
0.375 inches
MRC:
AKPX
Pole Quantity
3
MRC:
AXHR
Mounting Facility Type And Quantity
4 slot and 4 unthreaded hole
MRC:
CBBL
Features Provided
Adjustable trip release
MRC:
CPLM
Maximum Continuous Load Current Rating Per Pole
600.0 amperes ac all locations
MRC:
CPRF
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
MRC:
CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
MRC:
CPRH
Circuit Protection Type
Overcurrent all locations
MRC:
CPRJ
Trip Release Method
Magnetic all locations
MRC:
CPRL
Trip Release Characteristic
Instantaneous all locations and time delay all locations
MRC:
CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
MRC:
CPRP
Ultimate Trip Time Per Pole In Seconds
56.000 all locations
MRC:
CPRQ
Reset Method
Electric
MRC:
CPRR
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRT
Manual Actuator Type And Quantity
1 rotary
MRC:
CPRW
Actuator Function
Reset
MRC:
CPRX
Actuator Position Designation
At pole one
MRC:
CPRY
External Actuator Linkage Arrangement
One, two, and three linked
MRC:
CPRZ
Auxiliary Switch Function And Quantity
12 alarm
MRC:
CPSF
Adjustable Trip Setting Current Range Per Pole In Amps
+280.0/+460.0 ac all locations and +1750.0/+5250.0 ac all locations
MRC:
CPSM
Internal Trip Release Configuration
Shunt trip all locations
MRC:
CQTL
Reset Actuator Voltage Rating And Type In Volts
208.0 ac
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
75.000 at 100 pct all locations and 1000.000 at 100 pct all locations and 56.000 at 150 pct all locations and 200.000 at 150 pct all locations and 46.000 at 200 pct all locations and 300.000 at 200 pct all locations and 40.000 at 300 pct all locations and 150.000 at 300 pct all locations and 34.000 at 400 pct all locations and 90.000 at 400 pct all locations and 28.000 at 500 pct all locations and 65.000 at 500 pct all locations and 10.000 at 1000 pct all locations and 18.000 at 1000 pct all locations
MRC:
CRTK
Switch Terminal Type
Threaded stud
MRC:
CSSX
Switch Current Rating And Type In Amps
12.0 ac and 9.0 dc
MRC:
CSWP
Switch Voltage Rating And Type In Volts
208.0 ac and 120.0 dc
MRC:
FEAT
Special Features
Long delay pickup, long time delayband, instantaneous pickup settings adjustable.
MRC:
FREQ
Frequency In Hertz
60.0 all locations
MRC:
TTQY
Terminal Type And Quantity
6 bus bar
MRC:
--
NSN
5925001963997
MRC:
--
Supply Class
#5925 - Circuit Breakers
MRC:
--
PMIC
No precious metal content.
MRC:
--
HMIC
No information in HMIRS. Hazardous material unknown.
MRC:
--
Unit of Issue
EA
Manufacturers and Distributors
CAGE
Name
Part Numbers and Brands
Part Number
Brand
150-0866
Continental Electronics Corporation

  Certificates

Factory New (FN), New Material (NE), New Unused Surplus (NS), Overhauled (OH), Serviceable (SV), Repairable (RP), and AS Removed / Used (AR) material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable.