Manufacturer Datasheet
SKU: 5925-00-832-9953 Model: 52-258-1-MG3
MRC
Name
Detail
MRC:
AAQL
Body Style
Multipole-multiple actuator type
MRC:
ADAQ
Body Length
Between 3.709 inches and 3.729 inches
MRC:
ADAT
Body Width
Between 2.021 inches and 2.041 inches
MRC:
ADTV
Case Material
Plastic
MRC:
AEBP
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches
MRC:
AEBQ
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and 1.041 inches
MRC:
AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches
MRC:
AEGJ
Switch Contact Arrangement
Single pole, double throw
MRC:
AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and 1.041 inches
MRC:
AFJN
Fragility Factor
Moderately rugged
MRC:
AJEC
Boss Height
Between 0.146 inches and 0.166 inches
MRC:
AJWX
Mounting Surface To Terminal End Distance
3.239 inches
MRC:
AKPX
Pole Quantity
2
MRC:
APNQ
Arc Quenching Method
Magnetic blowout
MRC:
AXHR
Mounting Facility Type And Quantity
4 threaded hole
MRC:
BBRG
Storage Type
General purpose warehouse
MRC:
CMLP
Thready Qty Per Inch (tpi)
32
MRC:
CPLM
Maximum Continuous Load Current Rating Per Pole
28.0 amperes ac all locations
MRC:
CPRF
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
MRC:
CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
MRC:
CPRH
Circuit Protection Type
Overcurrent all locations
MRC:
CPRJ
Trip Release Method
Magnetic-hydraulic all locations
MRC:
CPRL
Trip Release Characteristic
Time delay all locations
MRC:
CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
MRC:
CPRQ
Reset Method
Manual
MRC:
CPRR
Main Contact Tripping Mechanism Type
Trip free
MRC:
CPRT
Manual Actuator Type And Quantity
2 toggle
MRC:
CPRW
Actuator Function
Trip-reset
MRC:
CPRX
Actuator Position Designation
At each pole
MRC:
CPRY
External Actuator Linkage Arrangement
One and two linked
MRC:
CPRZ
Auxiliary Switch Function And Quantity
1 alarm
MRC:
CPSM
Internal Trip Release Configuration
Series trip all locations
MRC:
CQJX
Thread Size
0.138 inches
MRC:
CQSM
Switch Location And Position Designation
Internal at pole one
MRC:
CQWN
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations
MRC:
CQXF
Inclosure Protection Type For Which Designed
Dustproof and fungus proof
MRC:
CRTK
Switch Terminal Type
Tab w/screw
MRC:
CSSX
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
MRC:
CSWP
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
MRC:
FREQ
Frequency In Hertz
60.0 all locations
MRC:
THSD
Thread Series Designator
Unc
MRC:
TTQY
Terminal Type And Quantity
24 threaded stud
MRC:
--
NSN
5925008329953
MRC:
--
Supply Class
#5925 - Circuit Breakers
MRC:
--
PMIC
Precious metal content is unknown.
MRC:
--
HMIC
No information in HMIRS. Hazardous material unknown.
Factory New (FN), New Material (NE), New Unused Surplus (NS), Overhauled (OH), Serviceable (SV),
Repairable (RP), and AS Removed / Used (AR) material will be accompanied by a Certificate of Conformance,
and any other documents/trace when applicable.
Delivery
Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.
Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.
Satisfaction
Your satisfaction is our success! At NationalStockNumber.parts
we believe that we have the best quality service out there. If you run
into any issues, we are here to solve them! Contact us by phone or email at any time.